Software Menus
Page 2
FactData > CfgData..
CfgData > UserData..
UserData > CfgData..
6.2 Menu System - Save-Load Menu
Comments:
FactData
This represents the factory
settings. The data are stored in FRAM
memory. The user can copy and change
these data in RAM, but these changes
cannot be saved as FactData.
UserData
A user’s own conguration can
be saved to FRAM memory and loaded
from FRAM.
CfgData
The conguration used at run-
time and stored in RAM.
At startup, the checksum of the congu-
ration is calculated. If an error occurs, the
user data are loaded into RAM, overwri-
ting the CfgData conguration.
This ensures that the instrument is always
ready for use.
This function replaces the current congura-
tion with factory settings.
This function stores the current conguration
as a user dataset in the FRAM memory.
This function replaces the current congura-
tion with the user dataset.
CAUTION!
All 3 functions overwrite internal data. Any
changes made since the last backup will be
undone.
Note!
These procedures require a further conrma-
tion to start.
Chapter 7 includes further details of the