Emerson Process Management HASX2E-IM-HS Carbon Monoxide Alarm User Manual


 
Emerson Process Management GmbH & Co. OHG2-8
X-STREAM X2
Instruction Manual
HASX2E-IM-HS
02/2012
2.2.1 Model-Specic Technical Data: X-STREAM X2GK
2.2.1.1 Data for Optional External Power Supply Units
Model UPS 01 T
This PSU can be ordered as an option for supplying power to one table-top unit.
Nominal input voltage
120 / 230 V 50/60 Hz
Input voltage range 95–138 V / 187–264 V , 47–63 Hz
Power consumption max. 240 VA
Connection via rubber connector
(IEC plug;
Fig. 2-2
).
Power input fuses
The PSU does not include user-replaceable
fuses.
Nominal output voltage
24 V (± 5 %)
Nominal output current 5 A
Output 3-pin XLR socket
Surge protection current limiting typ. 110% I
nom
,
straight response curve, short-circuit-proof
Excess temperature protection reduction of output voltage to
disconnection. Resets after cooling.
Weight approx. 2.5 kg (4.8 lb)
Certication
Safety EN 60950, UL1950, CSA22.2 NO 950-95
EMC EN 50081-1 (emitted interference)
EN 50082-2 (interference resistance), et al.