Mitsumi electronic MR-J3- A Air Conditioner User Manual


 
App. - 19
A
PPENDI
X
(8) Selection example of wires
To comply with the UL/C-UL Standard, use UL-approved copper wires rated at 60/75
(140/167 ) for
wiring.
The following table shows the wire sizes [AWG] and the crimping terminal symbols rated at 60
(140 ).
The sizes and the symbols rated at 75
(167 ) are shown in the brackets.
Servo amplifier
Converter
unit
(Note 3) Wires (AWG)
L
1
L
2
L
3
L
11
L
21
U
V W
P
1
P
2
P
P
2
C
MR-J3-10A(1) to 40A(1) 60A 70A
14(14)
16(16)
(Note 4) 14(14)
14(14)
MR-J3-100A 200A
MR-J3-350A 12(12) 12(12)
(Note 1) MR-J3-500A 10(10): a(a)
16(16): h(h)
10(10): a(a) 14(14): g(g)
(Note 1) MR-J3-700A 8(8): b(b) 8(8): b(b) 12(12): a(a)
(Note 1) MR-J3-11KA 6(6): c(c) 4(4): d(c)
10(10): j(j)
(Note 1) MR-J3-15KA 4(4): d(d) 16(16): g(g) 2(3): e(d)
(Note 1) MR-J3-22KA 1/0(1): f(p) (1): (p) 10(10): k(k)
(Note 1) MR-J3-DU30KA
MR-J3-
CR55K
(1): (t)
14(14)
(2/0): (u) 10(10): r(r)
(Note 1) MR-J3-DU37KA (2/0): (u)
MR-J3-60A4
MR-J3-100A4 14(14) 16(16) 14(14) 14(14)
MR-J3-200A4
MR-J3-350A4 14(14): g(g) 14(14): g(g)
(Note 1) MR-J3-500A4
10(12): a(a)
16(16): h(h) 10(12): a(a) 14(14): g(g)
(Note 1) MR-J3-700A4 10(10): a(a)
(Note 1) MR-J3-11KA4 8(10): l(j) 8(8): l(l) 12(12): j(j)
(Note 1) MR-J3-15KA4 6(8): c(l) 16(16): g(g) 4(6): d(c) 10(10): j(j)
(Note 1) MR-J3-22KA4 6(6): m(m) 4(6): n(m) 10(10): k(k)
(Note 1) MR-J3-DU30KA4 3(4): s(s) 2(3): p(n)
(Note 1) MR-J3-DU37KA4
MR-J3-
CR55K4
2(2): t(s)
14(14)
1(2): p(n)
10(10): r(r)
(Note 1) MR-J3-DU45KA4 (2): (t) (1/0): (t)
(Note 1) MR-J3-DU55KA4 (2): (t) (1/0): (t)