Mitsumi electronic MR-J3- A Air Conditioner User Manual


 
12 - 61
12. OPTIONS AND AUXILIARY EQUIPMENT
(6) Specifications
Power regenerative common converter
FR-CV-
Item
7.5K 11K 15K 22K 30K 37K 55K
Total of connectable servo amplifier capacities [kW] 3.75 5.5 7.5 11 15 18.5 27.5
Maximum servo amplifier capacity [kW] 3.5 5 7 11 15 15 22
Output
Total of connectable servo motor
rated currents [A]
33 46 61 90 115 145 215
Regenerative
braking torque
Short-time
rating
Total capacity of applicable servo motors, 300
torque, 60s (Note 1)
Continuous
rating
100
torque
Power supply
Rated input AC voltage/frequency 3-phase 200 to 220VAC 50Hz, 200 to 230VAC 60Hz
Permissible AC voltage fluctuation 3-phase 170 to 242VAC 50Hz, 170 to 253VAC 60Hz
Permissible frequency fluctuation 5
Power supply capacity (Note 2)
[kVA]
17 20 28 41 52 66 100
IP rating (JEM 1030), cooling system Open type (IP00), forced cooling
Environmental
conditions
Ambient temperature
10 to 50 (non-freezing)
Ambient humidity 90 RH or less (non-condensing)
Ambience Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt)
Altitude, vibration 1000m or less above sea level, 5.9m/s
2
or less
No-fuse breaker or leakage current breaker
30AF
30A
50AF
50A
100AF
75A
100AF
100A
225AF
125A
225AF
125A
225AF
175A
Magnetic contactor S-N20 S-N35 S-N50 S-N65 S-N95 S-N95 S-N125
Power regenerative common converter
FR-CV-H
Item
22K 30K 37K 55K
Total of connectable servo amplifier capacities [kW] 11 15 18.5 27.5
Maximum servo amplifier capacity [kW] 11 15 15 22
Output
Total of connectable servo motor
rated currents [A]
43 57 71 110
Regenerative
braking torque
Short-time
rating
Total capacity of applicable servo motors, 300
torque, 60s (Note 1)
Continuous
rating
100
torque
Power supply
Rated input AC Voltage, frequency 3-phase 380 to 480VAC, 50Hz/60Hz
Permissible AC voltage fluctuation 3-phase 323 to 528VAC, 50Hz/60Hz
Permissible frequency fluctuation 5
Power supply capacity [kVA] 41 52 66 100
IP rating (JEM 1030), cooling system Open type (IP00), forced cooling
Environmental
conditions
Ambient temperature
10 to 50 (non-freezing)
Ambient humidity 90 RH or less (non-condensing)
Ambience
Indoors (without corrosive gas, flammable gas, oil
mist, dust and dirt)
Altitude, vibration 1000m or less above sea level, 5.9m/s
2
or less
No-fuse breaker or leakage current breaker
60AF
60A
100AF
175A
100AF
175A
225AF
125A
Magnetic contactor S-N25 S-N35 S-N35 S-N65
Note 1. This is the time when the protective function of the FR-CV-(H) is activated. The protective function of the servo amplifier is
activated in the time indicated in section 11.1.
2. When connecting the capacity of connectable servo amplifier, specify the value of servo amplifier.