15 - 79
15. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
MC
RA2
External dynamic brake
24VDC
RA1
RA3
(Note 4)
RA2
L
1
L
2
L
3
L11
L
21
U
V
W
U
V
W
M
Servo motor
(Note 3)
Power
supply
L
L
L
L
L
L
L11
L
21
L
L
Drive unitConverter unit
(Note 1)
1MC1
2MC2
CNP1
15 SON
42 EMG
46
DOCOM
SDPlate
CN1
(Note 2)
DB
20
DICOM
47
DOCOM
ALM48
CN1
1
DICOM
5
DOCOM
6
DICOM
2ALM
7EM1
9
DOCOM
RA3
(Note 4)
Dynamic brake interlock
NFB
24VDC
RA1 RA2
OFF/ON
Comberter
unit trouble
Drive unit
trouble
Emergency stop
(EMG EM1)
(Note 4)
MC
Operation
ready
SK
13 W14 V U
a
b
Note 1 For converter unit and servo amplifier 400V class, stepdown transformer is required for coil voltage of magnetic contactor more
than 200V class.
2. Assign the dynamic brake interlock (DB) in parameter No.PD13 to PD16 and PD18.
3. Refer to section 15.1.3 for the power supply specifications.
4. Make up a sequence that will concurrently turn off the Emergency stop (EMG) of the drive unit and the Forced stop (EM1) of the
converter unit, and shut off the main circuit power supply by the external sequence.