A SERVICE OF

logo

12 - 13
12. OPTIONS AND AUXILIARY EQUIPMENT
(b) Internal wiring diagram
MR-EKCBL20M-L
Encoder sideServo amplifier side
1
2
3
4
3
7
9
Plate
1
2
8
9
LG
MR
MRR
SHD
P5
BAT
LG
MR
MRR
SHD
P5
BAT
(Note)
MR-EKCBL30M-L
Encoder sideServo amplifier side
P5
LG
1
2
MR
MRR
3
4
MDR 8 5
3
7
4
MD 7
9
SD
1
2
8
9
LG
MR
MRR
MDR
MD
SHD
P5
6CONT
BATBAT
Plate
(Note)
MR-EKCBL20M-H
Encoder sideServo amplifier side
Plate
1
2
3
4
3
7
9
1
2
8
9
LG
MR
MRR
SHD
P5
BAT
LG
MR
MRR
SHD
P5
BAT
(Note)
Encoder sideServo amplifier side
(Note)
Plate
P5
LG
1
2
MR
MRR
3
4
MDR 8 5
3
7
4
MD 7
9
SD
1
2
8
9
LG
MR
MRR
MDR
MD
SHD
P5
6CONT
BATBAT
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Note. Always make connection for use in an absolute position detection system. Wiring is not necessary for use in an incremental
system.
When fabricating the cable, use the wiring diagram corresponding to the length indicated below.
Cable flex life
Applicable wiring diagram
Less than 30m 30 to 50m
Standard MR-EKCBL20M-L
Long flex life MR-EKCBL20M-H MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H