6 - 11
6. DISPLAY AND OPERATION SECTIONS
6.6.2 Operation example
(1) Parameters of 5 or less digits
The following example shows the operation procedure performed after power-on to change the control
mode (Parameter No.PA01) into the speed control mode. Press "MODE" to switch to the basic setting
parameter screen.
Press four times. Select parameter No.8 withUP DOWN.orMODE
The parameter number is displayed.
UP DOWN
or
Press to change the number.
SET
Press twice.
The set value of the specified parameter number flickers.
UP
Press twice.
During flickering, the set value can be changed.
UP DOWN
or
Use .
SET
Press to enter.
( 2: Speed control mode)
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the parameter No.PA01 setting, change its set value, then switch power off once and
switch it on again to make the new value valid.