Mitsumi electronic MR-J3- A Air Conditioner User Manual


 
12 - 35
12. OPTIONS AND AUXILIARY EQUIPMENT
(d) MR-J3-11KA(4)-PX/LW
MR-J3-15KA(4)-PX/LW MR-J3-22KA(4)-PX (when using the regenerative
option)
The MR-J3-11KA(4)-PX to MR-J3-22KA(4)-PX servo amplifiers are not supplied with regenerative
resistors. When using any of these servo amplifiers, always use the MR-RB5E, 9P, 9F, 6B-4, 60-4 and
6K-4 regenerative option.
The MR-RB5E, 9P, 9F, 6B-4, 60-4 and 6K-4 are regenerative options that have encased the GRZG400-
1.5
, GRZG400-0.9 , GRZG400-0.6 , GRZG400-5.0 , GRZG400-2.5 , GRZG400-2.0
respectively. When using any of these regenerative options, make the same parameter setting as when
using the GRZG400-1.5
, GRZG400-0.9 , GRZG400-0.6 , GRZG400-5.0 , GRZG400-2.5 ,
GRZG400-2.0
(supplied regenerative resistors or regenerative option is used with 11k to 22kW servo
amplifier).
Cooling the regenerative option with cooling fans improves regenerative capability.
The G3 and G4 terminals are for the thermal protector. G3-G4 is opened when the regenerative option
overheats abnormally.
Regenerative option
Configure up a circuit which shuts off main circuit
power when thermal protector operates.
Servo amplifier
C
P
P
1
Do not
remove the
short bar.
5m or less
(Note)
P
C
G3
G4
Note. Specifications of contact across G3-G4
Maximum voltage : 120V AC/DC
Maximum current : 0.5A/4.8VDC
Maximum capacity : 2.4VA
Servo amplifier
Regenerative
option model
Resistance
[
]
Regenerative power [W]
Without
cooling fans
With
cooling fans
MR-J3-11KA-PX MR-RB5E 6 500 800
MR-J3-11KA-LW MR-RB5R 3.2 500 800
MR-J3-15KA-PX MR-RB9P 4.5 850 1300
MR-J3-15KA-LW
MR-J3-22KA-PX
MR-RB9F 3 850 1300
MR-J3-11KA4-PX MR-RB6B-4 20 500 800
MR-J3-11KA4-LW MR-RB5K-4 10 500 800
MR-J3-15KA4-PX MR-RB60-4 12.5 850 1300
MR-J3-15KA4-LW
MR-J3-22KA4-PX
MR-RB6K-4 10 850 1300