12 - 45
12. OPTIONS AND AUXILIARY EQUIPMENT
(2) Combination with MT-BR5-(H) resistor unit
RA4
(Note 3)
(Note 6)
FR-BU2-(H)
MT-BR5-(H)
(Note 5)
(Note 9)
P
1
P( )
N( )
(Note 8)
(Note 2)
C(Note 10)
MCNFB
BUE
SD
PR
B
C
A
SD
MSG
P
PR
TH2
TH1
L
1
L
2
L
3
L
11
L
21
CN1
21
DICOM
48 ALM
20
DICOM
46
DOCOM
42 EMG
15 SON
Plate SD
24VDC
RA1
RA4
OFF
MC
ON
MC
(Note 11)
SK
SK
N/
P/
RA1
ALM
Servo motor
thermal relay
RA2
(Note 7)
(Note 1)
Power
supply
Servo amplifier
Emergency
stop
(Note 11)
(Note 4)
Note 1. For power supply specifications, refer to section 1.3.
2. Always connect P
1 and P( ) terminals (Factory-wired). When using the power factor improving DC reactor, refer to section
12.13. Use only one of power factor improving DC reactor or power factor improving AC reactor.
3. Connect the P/
and N/ terminals of the brake unit to a correct destination. Incorrect connection results in servo amplifier
and brake unit malfunction.
4. For the servo amplifier of 400V class, a step-down transformer is required.
5. Contact rating: 1a contact, 110VAC_5A/220VAC_3A
Normal condition: TH1-TH2 is not conducting. Abnormal condition: TH1-TH2 is conducting.
6. Contact rating: 230VAC_0.3A/30VDC_0.3A
Normal condition: B-C is conducting/A-C is not conducting. Abnormal condition: B-C is not conducting/A-C is conducting.
7. For the servo amplifier of 11kW or more, connect the thermal relay censor of the servo amplifier.
8. Do not connect more than one cable to each P (
) and N ( ) terminals of the servo amplifier.
9. Always connect BUE and SD terminals (Factory-wired).
10. For the servo amplifier of 22kW, do not connect a supplied regenerative resistor to the P and C terminals.
11. Configure the circuit to shut down the main circuit power supply simultaneously with the turn off of emergency stop (EMG)
using the external sequence.