Mitsumi electronic MR-J3- A Air Conditioner User Manual


 
12 - 27
12. OPTIONS AND AUXILIARY EQUIPMENT
12.2 Regenerative options
CAUTION
The specified combinations of regenerative options and servo amplifiers may only
be used. Otherwise, a fire may occur.
(1) Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Servo amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-RB032
[40
]
MR-RB12
[40 ]
MR-RB30
[13 ]
MR-RB31
[6.7 ]
MR-RB32
[40 ]
(Note 1)
MR-RB50
[13
]
(Note 1)
MR-MB51
[6.7
]
MR-J3-10A (1) 30
MR-J3-20A (1) 10 30 100
MR-J3-40A (1) 10 30 100
MR-J3-60A 10 30 100
MR-J3-70A 20 30 100 300
MR-J3-100A 20 30 100 300
MR-J3-200A 100 300 500
MR-J3-350A 100 300 500
MR-J3-500A 130 300 500
MR-J3-700A 170 300 500
Servo amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-RB1H-4
[82
]
(Note 1)
MR-RB3M-4
[120
]
(Note 1)
MR-RB3G-4
[47
]
(Note 1)
MR-RB5G-4
[47
]
(Note 1)
MR-RB34-4
[26
]
(Note 1)
MR-RB54-4
[26
]
MR-J3-60A4 15 100 300
MR-J3-100A4 15 100 300
MR-J3-200A4 100 300 500
MR-J3-350A4 100 300 500
MR-J3-500A4 130 300 500
MR-J3-700A4 170 300 500
Servo amplifier
(Note 2) Regenerative power [W]
External regenerative
resistor (Accessory)
MR-RB5E
[6
]
MR-RB9P
[4.5 ]
MR-RB9F
[3 ]
MR-RB6B-4
[20 ]
MR-RB60-4
[12.5 ]
MR-RB6K-4
[10 ]
MR-J3-11KA 500 (800) 500 (800)
MR-J3-15KA 850 (1300) 850 (1300)
MR-J3-22KA 850 (1300) 850 (1300)
MR-J3-11KA4 500 (800) 500 (800)
MR-J3-15KA4 850 (1300) 850 (1300)
MR-J3-22KA4 850 (1300) 850 (1300)