Mitsumi electronic MR-J3- A Air Conditioner User Manual


 
13 - 14
13. COMMUNICATION FUNCTION
13.4.2 Write commands
(1) Status display (Command [8][1])
Command Data No. Description Setting range Frame length
[8][1] [0][0] Status display data erasure 1EA5 4
(2) Parameters (Command [8][4]
[8][5])
Command Data No. Description Setting range Frame length
[8][4] [0][1] to [F][F] Write of parameters
Writes the values of the parameters in the
parameter group specified with the command
[8][5]
data No.[0][0]. Before writing the values,
therefore, always specify the parameter group
with the command [8][5]
data No.[0][0].
The decimal equivalent of the data No. value
(hexadecimal) corresponds to the parameter
number.
Depending on the parameter 8
[8][5] [0][0] Parameter group write
0000: Basic setting parameter (No.PA
)
0001: Gain filter parameter (No.PB
)
0002: Extension setting parameter (No.PC
)
0003: I/O setting parameter (No.PD
)
0000 to 0003 4
(3) External I/O signal (Command [9][2])
Command Data No. Description Setting range Frame length
[9][2] [6][0] Communication input device signal Refer to section 13.5.5 8
(4) Alarm history (Command [8][2])
Command Data No. Description Setting range Frame length
[8][2] [2][0] Alarm history erasure 1EA5 4
(5) Current alarm (Command [8][2])
Command Data No. Description Setting range Frame length
[8][2] [0][0] Alarm erasure 1EA5 4
(6) I/O device prohibition (Command [9][0])
Command Data No. Description Setting range Frame length
[9][0] [0][0] Turns OFF the input device, external analog
input signal or pulse train input, except EMG,
LSP and LSN, independently of the external
ON/OFF status.
1EA5 4
[0][3] Disables all output devices (DO). 1EA5 4
[1][0] Cancels the prohibition of the input device,
external analog input signal or pulse train input,
except EMG, LSP and LSN.
1EA5 4
[1][3] Cancels the prohibition of the output device. 1EA5 4