15. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
15.9.4 Selection example of wires
POINT
Wires indicated in this section are separated wires. When using a cable for
power line (U, V, and W) between the drive unit and servo motor, use a 600V
grade EP rubber insulated chloroprene sheath cab-tire cable (2PNCT). For
selection of cables, refer to appendix 6.
To comply with the UL/CSA Standard, use the wires shown in appendix 10 for
wiring. To comply with other standards, use a wire that is complied with each
standard.
Selection condition of wire size is as follows.
Wire type: 600V Polyvinyl chloride insulated wire (IV wire)
Construction condition: One wire is constructed in the air
The following diagram shows the wires used for wiring. Use the wires given in this paragraph or equivalent.
Converter unit Drive unit Servo motor
C
P
1
P
2
L
1
L
2
L
3
L
11
L
21
V
U
W
V
U
W
Motor
Encoder
OHS1
OHS2
Cooling fan
BU
BV
BW
L
11
L
21
2) Control power supply lead
3) Motor power supply lead
6) Thermal relay
Encoder cable
5) Cooling fan
lead
3)
Power supply
1)
Power factor
improving
DC reactor
4) Regenerative option lead
Regenerative option
1) Main circuit power
supply lead
Power supply
Thermal
relay