12. OPTIONS AND AUXILIARY EQUIPMENT
12.11 Selection example of wires
POINT
Wires indicated in this section are separated wires. When using a cable for power
line (U, V, and W) between the servo amplifier and servo motor, use a 600V grade
EP rubber insulated chloroprene sheath cab-tire cable (2PNCT). For selection of
cables, refer to appendix 6.
To comply with the UL/CSA Standard, use the wires shown in appendix 10 for
wiring. To comply with other standards, use a wire that is complied with each
standard.
Selection condition of wire size is as follows.
Construction condition: One wire is constructed in the air
Wire length: 30m or less
(1) Wires for power supply wiring
POINT
Always use the 600V grade heat-resistant polyvinyl chloride insulated wire (HIV
wire) when using the HF-JP series servo motor.
The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
C
P
U
V
W
L
11
L
21
U
V
W
L
1
L2
L3
B1
B2
1) Main circuit power supply lead
Servo amplifier
3) Motor power supply lead
Servo motor
Power supply
Motor
Electro-
magnetic
brake
Encoder
4) Electromagnetic
brake lead
Encoder cable
2) Control power supply lead
(Note)
C
P
N
4) Regenerative option lead
Regenerative option
Cooling fan
BU
BV
BW
6) Cooling fan lead
Power supply
7) Thermal
OHS1
OHS2
Thermal
8) Power regenerative
converter lead
Power regenerative
converter
Note. There is no L3 for 1-phase 100 to 120VAC power supply.