NEC N 1093100 Water System User Manual


 
31xx-Configuration
311x-Options
3111-Features
818 Line Options: 3101-3714 DSX Software Manual
Yes (1) - Enabled
Default
Yes (1) - Enabled
3111-04: Enable MFC Group B
(MFC Group B)
For E1 lines only, use this option to enable or disable the MFC Dialing Group B supervisory signaling. Since
not all central ofces provide Group B signaling, set this option for compatibility with the connected telco.
Features
N/A
IntraMail Features
None
Options
No (0) - Disabled
Yes (1) - Enabled
Default
Yes (1) - Enabled
3111-05: Store and Forward
(Store and Forward)
Use this option to enable or disable Store and Forward for every line in the line group the user will access
when they dial a line access code or press a loop key. If enabled, the system buffers the user-dialed digits and
dials them on the line when the user has completed dialing. If disabled, manually dialed digits output on the
line as the user dials them. You should enable store and forward for every line in accessed line group.
Features
Central Ofce Calls, Placing (page 78)
IntraMail Features
None
Options
No (0) - Disabled
Yes (1) - Enabled
Default
No (0) - Disabled
3111-06: Station Message Detail Recording
(SMDR)
Use this option to enable or disable SMDR reporting for the line. If enabled, the SMDR report includes data
for the line. If disabled, the SMDR report does not include data for the line.
Features
Station Message Detail Recording (page 328)
IntraMail Features
None
Options
No (0) - Disabled
Yes (1) - Enabled
Default
Yes (1) - Enabled