NEC N 1093100 Water System User Manual


 
Flexible Numbering Plan
180 Features DSX Software Manual
Programming
1. In yes:
- In 1301-[01-10]: Function Type (page 620), assign another digit (except 3) to type 1 (operator
access).
- In 1301-[01-10]: Expected Number of Digits (page 620), change the expected digits option for the
new digit to 2.
- Be sure your choice does not affect other system operations.
2. If no, leave the above options at their default settings.
1. If yes:
- In 1301-[01-10]: Function Type (page 620), assign another digit (except 3) to type 3 (Line Group
access).
- In 1301-[01-10]: Expected Number of Digits (page 620), change the expected digits option for the
new digit to 2.
2. If no, leave the above options at their default settings.
1. If yes:
- In 1301-[01-10]: Function Type (page 620), assign another digit (except 3) to type 2 (extension
access).
- In 1301-[01-10]: Expected Number of Digits (page 620), change the expected digits option for the
new digit to 3.
- In 1313-01: Line Extension Number (page 625), change the line extension numbers to use the lead-
ing digit selected above.
2. If no, leave the above options at their default settings.
1. If yes:
- In 1301-[01-10]: Function Type (page 620), assign another digit (except 3) to type 2 (extension
access).
- In 1301-[01-10]: Expected Number of Digits (page 620), change the expected digits option for the
new digit to 3.
- In 1315-01: UCD Group Master Extension Number (page 627), change the master numbers to use
the leading digit selected above.
2. If no, leave the above options at their default settings.
1. If yes:
- In 1301-[01-10]: Function Type (page 620), assign another digit (except 3) to type 2 (extension
access).
- In 1301-[01-10]: Expected Number of Digits (page 620), change the expected digits option for the
new digit to 3.
- In 1314-01: Ring Group Master Extension Number (page 626), change the master numbers to use
the leading digit selected above.
2. If no, leave the above options at their default settings.
1. Do you want to change the digit(s) users dial to reach system operator(s)?
2. Do you want to change the digit(s) users dial to reach Line Groups?
3. Do you want to change the line extension number range used for Direct Line Access?
4. Do you want to change the UCD Group master extension number range?
5. Do you want to change the Ring Group master extension number range?