NEC N 1093100 Water System User Manual


 
Direct Inward Line
110 Features DSX Software Manual
Programming
Basic Programming
1. In 3101-01: Line Type (page 809), check to be sure the line’s circuit type matches the connected service.
2. In 3101-03: DTMF Dialing (page 811), indicate whether the line is DTMF (1) or Dial Pulse (0).
1. In the day:
- In 3112-01: Direct Termination in the Day (page 819), assign the DIL day mode termination. The
assignment can be:
- An extension
- A UCD Group master number
- The voice mail master number
- A Ring Group master number
2. At night:
- In 3112-04: Direct Termination at Night (page 820), assign the DIL day mode termination. The
assignment can be:
- An extension
- A UCD Group master number
- The voice mail master number
- A Ring Group master number
1. For a line terminated to Key Ring or a Ring Group master number during the day:
- In 2121-[01 to 24]: Feature Key Codes (page 758), enter 18.
- In 2121-[01 to 24]: Feature Key Data (page 758), press CLEAR.
2. For a line terminated to a UCD Group master number or voice mail during the day:
- In 2121-[01 to 24]: Feature Key Codes (page 758), enter 18.
-
In
2121-[01 to 24]: Feature Key Data (page 758)
, enter the UCD Group or voice mail master number.
3. For a line terminated to the extension during the day:
- Use the DND key.
4. Be sure the extension has the ability to put the system in the Night Mode.
- In 2102-01: Class of Service (page 724), check the extension’s Class of Service level.
- In 1402-05: Activate Night Mode (page 634), enter
Yes.
1. Check the DIL’s circuit type.
2. Assign the DIL day and night mode terminations (answering points).
3. Set up night keys for the DIL.