23xx-UCD Groups
231x-IntraMail (UCD Group Mailbox)
2313-Playback
DSX Software Manual Station Options: 2101-2501 ◆ 797
Station
2101-2501
• Group Mailbox (page 497)
Options
• No (0) - Disabled
• Yes (1) - Enabled
Default
• No (0) - Disabled
2313-04: Message Waiting Lamp
(MW Lamp)
Use this option to enable or disable Message Waiting lamping at the extension associated with the Sub-
scriber mailbox. For Subscriber Mailboxes, you should leave this option enabled. Disabling this option will
also disable Message Notification.
Features
• None
IntraMail Features
• Group Mailbox (page 497)
• Message Notification (page 535)
• Message Waiting Lamp (page 549)
• Subscriber Mailbox (page 574)
Options
• No (0) - Disabled
• Yes (1) - Enabled
Default
• Yes (1) - Enabled
2313-05: Recording Conversation Beep
(Rec Conv Beep)
Use this option to enable or disable the Conversation Record beep. If enabled, all parties on a call will hear
the voice prompt “Recording” followed by a beep when the extension user initiates Conversation Record. If
disabled, the voice prompt will not occur. When you disable the Conversation Record beep, the following
voice prompts do not occur while IntraMail records the conversation:
•“Recording” (followed by a beep)
•“That mailbox is full” (if the mailbox message storage capacity is reached)
•“You have reached the recording limit” (if the recorded message is too long)
Features
• None
IntraMail Features
• Conversation Record (page 462)
• Group Mailbox (page 497)
Options
• No (0) - Disabled
• Yes (1) - Enabled
Default
• Yes (1) - Enabled