NEC N 1093100 Water System User Manual


 
PBX / Centrex Compatibility
DSX Software Manual Features 271
Features
If 1551-04: Account Code Toll Restriction Level = 0
If an extension user:
- Seizes the line,
- Dials a valid PBX Access Code,
- Dials a number that begins with 0 or 1,
DSX requires the user to enter an Account Code for the call.
PBX/Centrex Access Codes and SMDR
The following occurs if a DSX line is programmed as a PBX line and access codes are properly entered in
the PBX Access Codes Table:
If an extension user dials a call that includes a valid PBX Access Code, the entire number dialed is
printed in the Number Dialed column and OUT is printed in the Type column (indicating that the call is
an outgoing call).
If an extension user dials a call that does not include a valid PBX Access Code, the entire number dialed
is printed in the Number Dialed column and PBX is printed in the Type column (indicating that the calls
is an internal PBX call).
Conditions
None
Default Setting
No PBX/Centrex Access Codes programmed.
Programming
1. In 3101-04: PBX Line (page 811), enter Yes.
- A line will only use the PBX Access Codes Table in step 2 if it is programmed as a PBX line.
1. In 3401-01: PBX Access Code Digits (page 838), enter the PBX access codes.
- You can enter up to 10 PBX Access Codes.
- Each code is either 1 or 2 digits long, using digits 0-9 and #.
- You can use * as a wild card character that can be entered in any position.
Other Related Features
Features
Speed Dial (page 315)
Speed Dial offers unique compatibility with connected Centrex services.
IntraMail Features
None
Operation
Operation is automatic when the feature is enabled in programming.
1. Specify which lines are PBX lines.
2. Enter PBX access codes into the PBX Access Codes Table.