NEC N 1093100 Water System User Manual


 
16xx-Timers
160x-Feature Timers
1602-Outgoing Call Timers
DSX Software Manual System Options: 1001-1702 671
System
1001-1702
1602-Outgoing Call Timers
Description
Use this program to adjust timers that affect outgoing calls.
Options
1602-01: Interdigit Timer
(Interdigit Time)
Use this option to set the Intercom interdigit time. When an extension user places a call, they must dial each
succeeding digit within this interval.
F
eatures
Central Ofce Calls, Placing (page 78)
Directory Dialing (page 131)
Intercom (page 211)
IntraMail Features
None
Options
1-9999 seconds
Default
6 seconds
1602-02: Line Response Timer
(Line Response)
When the system sends a line seize message to the ATRU/COIU PCB, it waits this interval for a response
from the line PCB. If the system gets no response within this interval, it marks the line as defective. Be sure
the value you enter is compatible with the local telco. If you set this value too short, the system may mark
properly functioning lines as defective. If too long, defective lines may be left in service.
Features
N/A
IntraMail Features
None
Options
4-1020 in 100 mS intervals (e.g., 10 = 1 second, 100 = 10 seconds).
Default
100 (10 seconds)
1602-03: Dialtone Detect Timer
(Dialtone Detect)
When the system seizes a line to place a Speed Dial call, it waits this interval for dial tone before outdialing
the call. The system requires that the rst dial tone be at least 5 seconds long and the second dial tone to be
at least 2.5 seconds long. Be sure the value you enter is compatible with the local telco. If you set this value
too short, the system may not seize properly functioning lines. If too long, there will be too long a delay
before the system skips over a defective line.
Features
Speed Dial (page 315)
IntraMail Features
None