NEC N 1093100 Water System User Manual


 
16xx-Timers
161x-COI (Analog Line) Timers
1612-Outgoing
DSX Software Manual System Options: 1001-1702 685
System
1001-1702
1612-Outgoing
Description
Use this program to adjust timers that affect outgoing calls on the line (COIU) PCBs.
Options
1612-01: DP Break Timer
(Break Time)
Use this timer to set the duration of the Dial Pulse Break signal (i.e., relay open). This is the “off” time in a
Dial Pulse digit. Set this timer for compatibility with the connected telco or PBX/Centrex. Keep in mind that
there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An
improper setting may cause misdialing.
F
eatures
Central Ofce Calls, Placing (page 78)
IntraMail Features
None
Options
4-1020 mS
Default
60 mS
1612-02: DP Make Timer
(Make Time)
Use this timer to set the duration of the Dial Pulse Make signal (i.e., relay closed). This is the “on” time in a
Dial Pulse digit. Set this timer for compatibility with the connected telco or PBX/Centrex. Keep in mind that
there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An
improper setting may cause misdialing.
Features
Central Ofce Calls, Placing (page 78)
IntraMail Features
None
Options
4-1020 mS
Default
40 mS
1612-03: DP Interdigit Timer
(Interdigit Time)
Use this timer to set the duration of the Dial Pulse Interdigit signal (i.e., relay open time between each digit).
Set this timer for compatibility with the connected telco or PBX/Centrex. Keep in mind that there are three
components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An improper setting
may cause misdialing.
Features
Central Ofce Calls, Placing (page 78)
IntraMail Features
None