NEC N 1093100 Water System User Manual


 
Paging
DSX Software Manual Features 261
Features
Conditions
None
Default Setting
All Call and Zone Paging allowed.
Ringing, Door Box chimes, and Background Music do not broadcast over External Paging.
Programming
Basic Programming
1. If yes:
- In 2113-05: Page Group (Zone) (page 740), assign the zone to which the extension belongs (1-7 or
0 for All Call only).
- In 2112-06: Paging Through Speaker (page 737), enter Yes.
2. If no:
- In 2112-06: Paging Through Speaker (page 737), enter No.
1. In 2102-01: Class of Service (page 724), check the extension’s Class of Service level.
2. If yes:
- For All Call Paging, 1407-01: Make All Call Page (page 644) enter Yes.
- For zones 1-7, in 1407-02: Make Page Into Zone 1 (page 644) through 1407-08: Make Page Into
Zone 7 (page 646) enter Yes.
3. If no:
- For All Call Paging, 1407-01: Make All Call Page (page 644) enter No.
- For zones 1-7, in 1407-02: Make Page Into Zone 1 (page 644) through 1407-08: Make Page Into
Zone 7 (page 646) enter No.
1. If yes, leave 1605-01: Page Duration Timer (page 680) at its current setting.
2. If no, adjust 1605-01: Page Duration Timer (page 680) as required.
1. To set up a Paging key on an extension:
- In 2121-[01 to 24]: Feature Key Codes (page 758), enter 13.
- In 2121-[01 to 24]: Feature Key Data (page 758), enter the zone number (
1-7 or 0 for All Call).
2. To set up a Paging key on a DSS Console:
- In 2402-[01-60]: DSS Console Key Codes (page 801), enter 13.
- In 2402-[01-60]: DSS Console Key Data (page 801), enter the zone number (
1-7 or 0 for All Call).
Page Relay Control
1. If yes:
- For relay 1, in 2101-06: Door Relay Assignment (page 723) for the Door Box extension enter 1.
1. Should extension be able to receive Paging announcements?
2. Should extension be able to place (broadcast) Paging announcements?
3. Is the maximum length of Paging announcements adequate?
4. Optionally set up a one-touch Paging Feature Key on an extension or DSS Console.
1. Do you want Paging to activate the associated DSX-40 control relay?