Cisco Systems 7000 Plumbing Product User Manual


 
6-128
Cisco SFS 7000 Series Product Family Command Reference Guide
OL-9163-02
Chapter 6 Show Commands
show ib sm switch
Examples The following example displays attributes of the InfiniBand switch with a guid of
00:05:ad:00:00:00:13:81:
SFS-7000P# show ib sm switch subnet-prefix fe:80:00:00:00:00:00:00 node-guid
00:05:ad:00:00:00:13:81
===============================================================
Subnet Management Switches
===============================================================
subnet-prefix : fe:80:00:00:00:00:00:00
node-guid : 00:05:ad:00:00:00:13:81
linear-fdb-cap : 49152
random-fdb-cap : 0
linear-fdb-top Specifies the top of the linear forwarding table. Packets that were received
with unicast LIDs greater than this value are discarded by the switch. This
parameter applies only to switches that implement linear forwarding tables.
Switches that implement random forwarding tables ignore this parameter.
default-port Specifies the default port to which to forward all the unicast packets from
other ports when the destination location ID (DLID) does not exist in the
random forwarding table.
default-pri-mcast-port Specifies the default port to which to forward all the multicast packets from
other ports when the DLID does not exist in the multicast forwarding table.
def-non-pri-mcast-port Specifies the port to which to forward all the multicast packets from
default-pri-mcast-port when the DLID does not exist in the multicast
forwarding table.
life-time-value Specifies the duration a packet can live in the switch. Time units are in
milliseconds. See section 18.2.5.4, Transmitter Queueing, InfiniBand
Architecture®, Vol. 1, Release 1.1, for more information.
port-state-change Indicates a change in port state. The value changes from NotInTransition to
PortInTransition anytime the State parameter of a port changes from down to
initialize, initialize to down, armed to down, or active to down, as a result of
link state machine logic.
lid-per-port Number of LID/LMC combinations that may be assigned to a given external
port for switches that support the random forwarding table. This value is
always 0. 0 indicates one LID per port.
partition-enf-cap Number of entries in this partition enforcement table per physical port. 0
(zero) indicates that the Server Switch does not support partition
enforcement.
in-enf-cap Indicates if the switch can enforce partitions on received packets. The value
appears as true or false.
out-enf-cap Indicates if the Server Switch can enforce partitions on transmitted packets.
The value appears as true or false.
in-filter-raw-pkt-cap Indicates if the Server Switch can enforce raw packets on received packets.
The value appears as true or false.
out-filter-raw-pkt-cap Indicates if the switch enforces raw packets on transmitted packets. The value
appears as true or false.
Table 6-44 show ib sm switch Command Field Descriptions (continued)
Field Description