(From the previous page)
*1 The monitoring interval is 1 to 600 (in units of 0.1 seconds) or 1 to 32767 (in units of seconds).
*2 When the database is Microsoft
®
Access
®
2000/2003/2007/2010/2013, refer to the following.
Section 2.6.3 Precautions for using database
*3 [No. of samples] can be set up to 20.
*4 The following shows the method for roughly calculating the buffering duration from the buffering
capacity.
Buffering duration = (No. of executable bufferings)(Execution frequency [times/hour]) [h]
No. of executable bufferings = (Usage capacity)(SQL text length + Overhead (4 bytes) [cases]
SQL text length = Total field character length + 6 × No. of fields + Total data length + 20 [bytes]
[Calculation example]
Accessing to 256 fields with 1 job and 1 action and performing every 30 seconds when capacity:
64 M bytes, field name: 16 characters, data length: 32 characters
SQL text length = (16 × 256) + 6 × 256 + (32 × 256) + 20 = 13844 [bytes]
No. of executable bufferings = (64 × 1024 × 1024)(13844 + 4) 4846 [cases]
Buffering duration = 4846(6030 × 60) 40 [h]
Table 3.2 MX MESInterface performance specifications
Item Specifications
Reference
section
DB interface
Device tag
No. of access target
CPU settings
64 settings/project Section 7.7
No. of tags 64 tags/project
Section 7.8.3
No. of components
256 components
*2
/tag
4096 components/project
Data type
Signed single-precision integer type (16 bits), signed double-
precision integer type (32 bits), single-precision floating point type
(32 bits), bit type, character string type (1 to 32 characters),
16-bit BCD type, 32-bit BCD type
Statistical processing
Average, maximum, minimum, moving average
*3
, moving
maximum
*3
, moving minimum
*3
DB buffering
Buffering capacity during
communication error
*4
Maximum capacity: CompactFlash card capacity - 32M bytes
(16 M bytes to 512 M bytes)
Section 7.6.4
XML processing
Command type One-shot execution of a job, enabling the job, disabling the job
CHAPTER 9
Request message size Maximum 128 k bytes
Reception protocol HTTP1.0
User authentication
No. of accounts: 16
User ID: 1 to 20 characters
Password: 6 to 14 characters
Working log
Error log capacity
Maximum capacity: 1 M byte
• At least 4800 logs can be recorded.
Section 7.12.5
Event log capacity
Maximum capacity: 4 M bytes
• At least 4800 logs can be recorded. (When there is no detailed log)
• At least 2 logs can be recorded. (When there is a detailed log)