Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
7
MES INTERFACE FUNCTION CONFIGURATION TOOL
7.13 Online - Remote operation
7.13.5 Checking the operation status of DB buffering
7
- 141
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
SETTINGS AND
PROCEDURE TO
OPERATION
5
INSTALLATION AND
UNINSTALLATION
6
FUNCTIONS
7
MES INTERFACE
FUNCTION
CONFIGURATION TOOL
8
DB CONNECTION
SERVICE AND
SETTING TOOL
*1 The startup log can be checked from [Online] - [Working log].
Section 7.12.5 Checking the working log of the MES interface module
*2 [Enable detailed logging] is selectable only when [Test mode] is selected in [Job settings].
Section 7.10.1
When [Enable detailed logging] is checked, [Enable startup logging] is also selected.
The detailed log can be checked from [Online] - [Working log] - [View details].
Section 7.12.5 Checking the working log of the MES interface module
*3 When marking a check in [Disable writing to database], the following is executed.
Execute [Communication action] set in a job and send rollback at the end.
When the following items exist, an error will occur.
[Server Service setting]: IP address, port number, user name, password, data source name
[Communication action]: Table name, field name
When the database is Wonderware
®
Historian, the following SQL text is sent during execution
of [Communication action] that is set in the job.
SQL text: "INSERT INTO History (DataTime, TagName, Value) SELECT TOP 0 NULL, NULL,
NULL :"
When any one of the following items is incorrect, an error will occur.
[Server Service setting]: IP address, port number, user name, password, data source name
An error will not occur even when [Communication action] is incorrectly set.
3 Clicking the button changes the job status.
4
7.13.5 Checking the operation status of DB buffering
The current and past maximum values of No. of DB buffering data and buffer utilization
can be viewed.
*1 The buffer utilization is stored as an integer. (Digits after decimal point is truncated.)
Utilization rates of the Automatically resend buffer and Manually resend buffer are compared, and
the greater buffer utilization rate is displayed.
*2 The maximum values are cleared when the MES interface module power is turned OFF.
When power is reapplied, No. of bufferings and Buffer utilization at the time are displayed as
maximum values.
*3 The space is displayed as blank during data acquisition or in the case of failure of data acquisition.
When the buffer utilization is high, ensure the capacity of the CompactFlash card.
Section 7.6.4 (7) DB buffering capacity (Range: 16MB to 512MB, Default:
64MB)
Figure 7.110 [DB buffering status]
Table 7.97 Items displayed in [DB buffering status]
Display
Description
Now
Maximum
*2
No. of bufferings
*3
Displays the current number of
buffered data (jobs that have been
buffered).
Displays a past maximum value in the
number of buffered data (jobs that
have been buffered).
Buffer utilization
*1 *3
Displays the current buffer utilization.
Displays a past maximum value in the
buffer utilization.
Execute