7.9 Server Service Setting
7.9.1 Setting items in Server Service setting
7
MES INTERFACE FUNCTION CONFIGURATION TOOL
7.9.1 Setting items in Server Service setting
Up to 32 items can be set in [Server service settings] within one project.
Figure 7.41 [Server service settings]
Table 7.42 Setting items in [Server service settings]
Item Description
Sever service name Enter a server service name. (Up to 16 characters)
Server type Select the server type of the server computer to be accessed.
IP address
Enter a decimal IP address of the server computer where DB Connection
Service is installed.
Port No.
Set a port number of the server computer.
(Range: 1024 to 65535, Default: 5112)
User name
Set a user name used to access the server computer.
(Up to 30 characters)
Password/Confirm
password
Set a password used to access the server computer.
(Up to 30 characters)
Data source name
Set the name of the ODBC data source to be accessed.
(Up to 30 characters)
Database type Select the type of the database server.
Access error notification
setting
Set whether to enable or disable notification of the access error status.
Connection timeout
In case a connection error occurs on the network between the MES
interface module and the server computer, set a timeout time during which
the MES interface module will detect the error.