Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
TROUBLESHOOTING
10.2 Error Code List
10.2.2 Error codes of DB Connection Service
10
- 35
9
XML MESSAGE
FORMAT
10
TROUBLESHOOTINGAPPENDICESINDEX
(3) SQL failure log of DB Connection Service
*1 [Database error number] and [Database error message] are output to the space after Database
Message in the SQL failure log of DB Connection Service.
For the output log format, refer to the following.
Section 8.8.2 SQL failure log
Table 10.8 SQL failure log output error list of DB Connection Service
Error code Error description and cause Corrective action
0x20600001 Failed in SQL execution due to insufficient memory.
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
0x20600002
*1
Failed in SQL execution due to insufficient
resources.
0x20600020
DB Connection Service does not support the SQL
instruction to be executed.
• Check if the source IP address belongs to the
MES interface module or the configuration
computer.
• Check the version of the MES interface module
or MES Interface Function Configuration Tool.
0x20600021
*1
Failed in preparation before SQL execution.
• Set a correct database type in [Server service
settings] of MES Interface Function
Configuration Tool.
• Select [Job settings] - [Communication action] in
MES Interface Function Configuration Tool, and
set a correct table name.
0x20600022
*1
Failed to obtain the number of fields in the record
that is to be obtained by the SQL execution.
0x20600023
*1
Failed in SQL execution.
• Set a correct database type in [Server service
settings] of MES Interface Function
Configuration Tool.
• Select [Job settings] - [Communication action] in
MES Interface Function Configuration Tool, and
set a correct table name, field names, and
Select/Update/Delete conditions.
Also, set a correct data type for the data entered
in the fields.
• Check if the uniqueness constraint of the
database (PRIMARY KEY constraint) is violated
or not.
• Check that reserved terms of the database are
not set for table names and field names.
0x20600024 System error
• Please consult your local Mitsubishi
representative.
0x20600025
No record was updated, inserted, or deleted by the
SQL execution.
• Select [Job settings] - [Communication action] in
MES Interface Function Configuration Tool, and
set update, insert, or delete conditions correctly.
• Check if the database has been filled with
registered data.
0x20600026
to
0x20600028
System error
• Please consult your local Mitsubishi
representative.
0x2060002B
(Data source name: *** Transmitting Commit
Success Response Failed. ***)
Failed to transmit the COMMIT success response.
• Check if it is connected to the network.
• Check if the gateway and/or hub is operating.
• Check if the power of the module is not turned
off.