Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
7
- 138
7.13 Online - Remote operation
7.13.2 Manipulating the operation status of the MES interface function
7
MES INTERFACE FUNCTION CONFIGURATION TOOL
(3) Update settings
1 After writing the MES interface function settings, select the [Update settings]
radio button.
Clicking the button restarts the MES interface module and updates the
settings.
For writing the MES interface function settings, refer to the following:
Section 7.12.2 Writing the MES interface function settings
When [Update settings] is performed, the operation behavior is as follows:
1) During the setting update, the MES interface function is temporarily stopped.
No job is executed during the stop.
2) After the setting update, the MES interface function is operated.
3) The data changed in [Change job status] are cleared.
Section 7.13.4 Changing the job status
4) The written MES interface function settings are updated.
5) The trigger buffer area and the DB buffer area are cleared.
[Update settings] may change the programmable controller CPU control.
Ensure the safety before executing it.
(4) Clear error
1 When [Error status] is [Continuation error], take corrective actions to remove the
error cause. Then, select the [Clear error] radio button and click the
button. Doing so clears the error status.
The ERR. LED on the MES interface module turns off.
The Current error area (buffer memory address: 140 to 145) is cleared.
The latest error code displayed in [System monitor] of GX Developer is
cleared. ( Section 10.1.3 System monitor)
Execute