MES INTERFACE FUNCTION CONFIGURATION TOOL
7.8 Device Tag Setting
7.8.3 Setting items in Component setting
7
- 47
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
SETTINGS AND
PROCEDURE TO
OPERATION
5
INSTALLATION AND
UNINSTALLATION
6
FUNCTIONS
7
MES INTERFACE
FUNCTION
CONFIGURATION TOOL
8
DB CONNECTION
SERVICE AND
SETTING TOOL
(1) Component name (Up to 16 characters)
Enter a component name.
For characters that can be used for component names, refer to the following:
Appendix 2.2 Characters that can be used for item names, component names,
variable names, etc. in the product
(2) CPU name
Select one from a list of the access target CPU names set in [Access target CPU
settings].
If [High-speed sampling] is selected, the choice is fixed to the first item in [Access
target CPU settings] (Control CPU).
(3) Head device
(a) Set a device type and an actual device number.
(b) Indexing, digit specification, and word device specification by bit specification are
not allowed.
(c) For accessible devices, refer to the following:
Section 3.2 Accessible Devices and Ranges
(d) When [block] is selected in [Array setting], different kinds of devices cannot be
set.
(e) Set device points as follows:(The number of the set points can be checked on the
status bar of [Device tag settings].)
96 points when [High-speed sampling] is selected.
40000 points when [Array setting] is set.
(4) Data type
Select the data type of sampling data (device data).
*1 When [Data type] is [String], device values are processed as follows:
When the device value neither an ASCII code nor shifted JIS code
It is replaced with "." (period: 2Eh).
MES interface module cannot access Unicode character data in RCPU.
When the device value is model-dependent characters
The character code may be converted during action execution.
Appendix 2.2 Characters that can be used for item names, component names, variable
names, etc. in the product
When the device value is a termination character (NULL code: 00h)
The character data following it are ignored. (The character string is regarded as terminated.)
Table 7.39 Options of [Data type]
Item Description
Selectable
device
Single word Handles data as single word data (16-bit Integer type). Word
Double word Handles data as double word data (32-bit Integer type). Word
Real number Handles data as floating point data. Word
Bit Handles data as bit data (in units of bits (0/1)). Bit
String
*1
Handles data as character strings. Word
16bit BCD Handles data as 16-bit BCD data. Word
32bit BCD Handles data as 32-bit BCD data. Word