Table 10.3 Error codes for the MES interface module
Error code Error name Description Action
FFF5h
System error
• Please consult your local Mitsubishi
representative.
FFF8h
FFFAh
FFFBh Size error
The device size exceeded the device
range.
• Correct the device number entered
in [Device tag settings].
FFFCh CPU error An invalid station was specified.
• Check the settings of the network
module on the access route.
• Check the station number setting in
[Access target CPU settings].
FFFDh Device type error The device type is incorrect.
• Correct the device type entered in
[Device tag settings].
FFFEh Device No. error The device number is incorrect.
• Correct the device number entered
in [Device tag settings].
FFFFh System error