Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
APPENDICES
Appendix 4 Processing Time
Appendix 4.1 Product whose first five digits of serial No. is "13092" or later
App
- 53
9
XML MESSAGE
FORMAT
10
TROUBLESHOOTINGAPPENDICESINDEX
Appendix 4 Processing Time
This section explains the processing time required for "communication action" as a result
of measurements made under the conditions shown in (1).
The processing time can be lengthened, however, depending on any of the following
factors:
Operating environment (personal computer, network, and the CompactFlash card)
Loading status of the server computer and the network
Sequence scan time
Accessing status from a personal computer, terminal display, or intelligent
function module to the programmable controller CPU
Access from a personal computer by MES Interface Function Configuration Tool
and XML processing
Settings of the MES interface module
Use the measurement result shown in (2) as reference of the processing time.
Appendix 4.1 Product whose first five digits of serial No. is "13092" or later
(1) Measurement conditions
(To the next page)
Table App.64 Measurement conditions
Item Description
Server computer
CPU Intel Core i7 2.8GHz
Memory 3GB
Operating system
Microsoft
®
Windows Server
®
2008 (32-bit version)
Database
Oracle
®
11g R2
Access target
CPU
Programmable controller
CPU
In the case of Select, Update or Insert
Q25HCPU (control CPU on own station)
In the case of MultiSelect
Q06UDHCPU (control CPU on own station)
Network No other station specified (Own station)
Sequence scan time 1ms
Device tag
settings
No. of tags
For trigger conditions: 1 tag
In the case of Select, Update or Insert
For communication data:
1 tag (for 16, 64, 256 fields)
4 tags (for 1024 fields)
16 tags (for 4096 fields)
In the case of MultiSelect
For receive data:
1 tag (Use array)
Sampling setting
For trigger conditions:
High-speed sampling (1 × 100ms)
For communication data: Do not sample
Data type
For trigger conditions: Bit transmit/receive
For data: Single precision