7.10 Job Setting
7.10.3 Setting items in Program execution
7
MES INTERFACE FUNCTION CONFIGURATION TOOL
(1) Execute program before action, or Execute program after action
(a) Set whether or not to enable program execution before or after execution of
actions.
(b) When [Execute program before action] or [Execute program after action] is
enabled, make the setting described in (2) and subsequent sections.
(2) Program execution destination
Select an application server to be accessed.
(3) Command line (Up to 127 characters)
Enter a command line for the program that is executed on the application server
computer.
*1 *2
For characters that can be used for command lines, refer to the following:
Appendix 2.3 Characters available for character string constants, etc.
*1 Programs that need to be run with administrator privileges (by a user in Administrators group) are
not executable.
*2 To execute a program including any displays, place the application server computer into the logon
status.
Figure 7.62 [Program execution settings after action execution]
Table 7.56 Setting items when selecting [Program execution settings before action execution] or
[Program execution settings after action execution]
Item Description
Execute program before
(after) action
Set whether or not to enable program execution before or after execution
of actions.
Program execution
destination
Select an application server to be accessed.
Command line
Enter a command line for the program that is executed on the application
server computer. (Up to 127 characters)
Check return value Set whether to check the return value or not.
Wait for execution
completion
Set whether or not to wait for execution completion of the program before
executing the next processing.