(4) Time specification startup
(a) When the specified date, time and day of the week match the actual date, time
and day of the week, the condition changes from false to true, resulting in job
startup.
(b) When [Time specification startup] is selected, the date, time, and day of the week
must be set.
1) Year, Month, Day, Hour, and Minute
Directly enter the date and time.
Matching with the actual date and time is not checked for any field that remains
blank.
2) Day:
Specify a day of the week.
Check the checkbox of the day to be specified.
If no box is checked, it means "every day".
(Example) The following shows that the job is to be activated at 17:30 on
Monday through Friday.
(Example) The following shows that the job is to be activated at 9:00 on the 1st
day of every month.
If [Startup logging] is selected, each job startup can be confirmed with the time to
the second in the startup log.
The startup log can be checked from [Online] - [View working log].
Section 7.12.5 Checking the working log of the MES interface module
Figure 7.45 [Time specification startup]
Table 7.50 Setting items in [Time specification startup]
Item Description
Year (4 digits) 1000 to 9999
Month 1 to 12
Day 1 to 31
Hour 0 to 23
Minute 0 to 59
Figure 7.46 [Time specification startup] setting example 1
Figure 7.47 [Time specification startup] setting example 2