Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
- 34
10.2 Error Code List
10.2.2 Error codes of DB Connection Service
10
TROUBLESHOOTING
(From the previous page)
*1 [Database error number] and [Database error message] are output to the space after Database
Message in the access log of DB Connection Service.
For the output log format, refer to the following.
Section 8.8.1 Access log
Table 10.7 Access log output error list of DB Connection Service
Error code Error description and cause Corrective action
0x20C00009
0x20C0000A
Failed to execute SQL when acquiring field names
from the database
• Set the database type of the DB server setting
correctly with the MES Interface Function
Configuration Tool.
• Check if there is any problem in the connection
route.
0x20C0000B
to
0x20C0000D
System error
• Please consult your local Mitsubishi
representative.
0x20C0000E
The database type set for the DB server setting is
different from the actual database type.
• Set the database type of the DB server setting
correctly with the MES Interface Function
Configuration Tool.
0x20C0000F
System error
• Please consult your local Mitsubishi
representative.
0x2FE00010