Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
TROUBLESHOOTING
10.2 Error Code List
10.2.2 Error codes of DB Connection Service
10
- 31
9
XML MESSAGE
FORMAT
10
TROUBLESHOOTINGAPPENDICESINDEX
(From the previous page)
(To the next page)
Table 10.7 Access log output error list of DB Connection Service
Error code Error description and cause Corrective action
0x20600021
*1
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in preparation before SQL execution.
• Set a correct database type in [Server service
settings] of MES Interface Function Configuration
Tool.
• Select [Job settings] - [Communication action] in
MES Interface Function Configuration Tool, and
set a correct table name.
0x20600022
*1
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed to obtain the number of fields in the record
that is to be obtained by the SQL execution.
0x20600023
*1
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in SQL execution.
• Set a correct database type in [Server service
settings] of MES Interface Function Configuration
Tool.
• Select [Job settings] - [Communication action] in
MES Interface Function Configuration Tool, and
set a correct table name, field names, and Select/
Update/Delete conditions.
Also, set a correct data type for the data entered
in the fields.
• Check if the uniqueness constraint of the
database (PRIMARY KEY constraint) is violated
or not.
• Check that reserved terms of the database are
not set for table names and field names.
0x20600024 System error
• Please consult your local Mitsubishi
representative.
0x20600025
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
No record was updated, inserted, or deleted by the
SQL execution.
• Select [Job settings] - [Communication action] in
MES Interface Function Configuration Tool, and
set update, insert, or delete conditions correctly.
• Check if the database has been filled with
registered data.
0x20600026
to
0x2060002A
System error
• Please consult your local Mitsubishi
representative.
0x2060002B
(SID [Session ID]: *** Transmitting Commit
Success Response Failed. ***)
Failed to transmit the COMMIT success response.
• Check if it is connected to the network.
• Check if the gateway and/or hub is operating.
• Check if the power of the module is not turned off.
0x20700001
(ProgramExec: [IP address]: <...>: Failed)
Failed in program execution due to insufficient
memory.
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
0x20700002
(ProgramExec: [IP address]: <...>: Failed)
Failed in program execution due to insufficient
resources.
0x20700003 System error
• Please consult your local Mitsubishi
representative.