Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
- 30
10.2 Error Code List
10.2.2 Error codes of DB Connection Service
10
TROUBLESHOOTING
(From the previous page)
(To the next page)
Table 10.7 Access log output error list of DB Connection Service
Error code Error description and cause Corrective action
0x20400020
*1
(SID [Session ID]: DB Connect: [Data source]:
[User]: Failed)
Failed to create a DB handle.
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
0x20400021 System error
• Please consult your local Mitsubishi
representative.
0x20400022
*1
(SID [Session ID]: DB Connect: [Data source]:
[User]: Failed)
Failed in DB connection.
• Set correct data source name, user name, and
password in [Server service settings] of MES
Interface Function Configuration Tool.
• To use a 64-bit version operating system for the
server, type the following at the command
prompt to start the "ODBC Data Source
Administrator".
%SystemRoot%\SysWOW64\odbcad32.exe
0x20400023
System error
• Please consult your local Mitsubishi
representative.
0x20500011
0x20500012
0x20500020
to
0x20500022
0x20600001
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in SQL execution due to insufficient memory.
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
0x20600002
*1
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in SQL execution due to insufficient
resources.
0x20600010
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Invalid SQL execution request
• Check if the source IP address belongs to the
MES interface module or the configuration
computer.
• Check the version of the MES interface module
or MES Interface Function Configuration Tool.
0x20600011
System error
• Please consult your local Mitsubishi
representative.
0x20600012
0x20600020
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
DB Connection Service does not support the SQL
instruction to be executed.
• Check if the source IP address belongs to the
MES interface module or the configuration
computer.
• Check the version of the MES interface module
or MES Interface Function Configuration Tool.