Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
7
- 64
7.10 Job Setting
7.10.2 Setting items in Trigger conditions
7
MES INTERFACE FUNCTION CONFIGURATION TOOL
(2) Trigger 1, Trigger 2
Select items for [Trigger 1] and [Trigger 2], referring to (3) and subsequent
descriptions.
: Selectable,
×
: Not selectable
(3) Disable
(a) When [Disable] is selected for [Trigger 1] or [Trigger 2]
Another trigger is regarded as a trigger condition.
(b) When [Disable] is selected for both [Trigger 1] and [Trigger 2]
The job is not activated by trigger conditions.
When [Disable] is selected, the job can be activated by an "instruction of job
execution" of the XML processing function.
Section 6.2 XML Processing Function
Table 7.49 Selection items for [Trigger 1] and [Trigger 2]
Item Description Trigger 1 Trigger 2
Disable
No trigger conditions
(3) Disable in this section
Time specification startup
When the specified date, time and day of the
week match the actual date, time and day of
the week, the condition changes from false to
true, resulting in job startup.
(4) Time specification startup in this
section
Specified time period
startup
The condition is alternated between true and
false in the specified cycles (unit: seconds),
and when it changes from false to true, the job
is activated.
(5) Specified time period startup in this
section
Value monitoring startup
The actual tag component value is compared
with the condition value (tag component value
or constant value) at every sampling times,
and the job is activated when the condition
changes from false to true.
(6) Value monitoring startup in this
section
At module startup
The job is activated only once when the MES
interface module is started up.
(7) At module startup in this section
Handshake operation
The job is activated when [Handshake startup]
of the programmable controller CPU turns
ON.
Upon completion of the job execution,
[Completion notification] of the programmable
controller CPU turns ON.
(8) Handshake operation in this section
×