Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
- 10
10.2 Error Code List
10.2.1 Error codes for the MES interface module
10
TROUBLESHOOTING
(From the previous page)
(To the next page)
Table 10.3 Error codes for the MES interface module
Error code Error name Description Action
0495h CF card check error
Failed to check the CompactFlash
card.
• Check the CompactFlash card for
any error. (Perform check disk on
the personal computer.)
0496h CF card response error
The access to the CompactFlash card
timed out while waiting for a response
from the card. (CompactFlash card
failure)
• Replace the CompactFlash card
with another.
04D0h Battery error
The battery voltage dropped, or the
battery connector was disconnected.
• Replace the battery.
• Check the battery connection.
0501h CPU fault detected
An error was detected from the CPU
of the module mounting station.
• Check the CPU status of module
mounting station.
0502h APS mismatch
APS of the request packet does not
match the one of the response packet.
The Start I/O specified in [Access
target CPU settings] is incorrect.
• Retry the transmission.
• Correct [Access target CPU
settings].
0604h
Setting file error
Failed to read out the setting file. (The
setting file is corrupted.)
• Retry writing the setting with MES
Interface Function Configuration
Tool.
0607h
060Ah Component device error
The device name specified in the
"component setting" is incorrect.
Or, an invalid device was specified.
• Correct the device specified in the
"component setting".
0610h
Access target CPU setting
error
Information on the network
communication route set in [Access
target CPU settings] is corrupted.
• Initialize the module, and then
configure the [Access target CPU
settings] again.
0617h Module stop error
Unable to handle the processing due
to a module stop error.
• Remove the cause of the module
stop error, and reset the
programmable controller CPU.
0618h
Setting update time-out
error
Because the load applied to the
module is high, setting update timed
out.
• Re-execute the setting update.
• Reset the programmable controller
CPU.
0619h Device name error
The device name specified in [Device
tag settings] is erroneous or invalid.
• Refer to the accessible device list,
and reenter a correct device name.
061Ah
BCD type conversion
error
A value which cannot be properly
expressed in BCD type was stored in
the device.
• Check the settings in [Device tag
settings].
• Check if the value stored in the
device can be properly expressed in
BCD type.
0626h Multiple CPU setting error
Invalid multiple CPU settings was
configured in [Access target CPU
settings].
• Correct [Access target CPU
settings].
0627h
Network communication
route error
The network No, head I/O, or station
No. of the network route, which was
specified in [Access target CPU
settings], is out of range.
0628h
Tag sampling interval
setting error
The sampling interval set in [Device
tag settings] is invalid.
• Correct [Device tag settings].
0629h
Setting file error
Failed to read out the setting file. (The
setting file is corrupted.)
• Retry writing the setting with MES
Interface Function Configuration
Tool.
062Ah
062Ch
062Dh
No CPU specification
error
The access target CPU specified in
the "component setting" does not
exist, or its setting was deleted.
• Specify an existing CPU as the
access target.