7.10 Job Setting
7.10.5 Setting items for job cancellation
7
MES INTERFACE FUNCTION CONFIGURATION TOOL
7.10.5 Setting items for job cancellation
Set whether to enable or disable notification of errors (job cancellation) that occur during
job execution.
Job execution is canceled when access to the database fails or when type mismatch is
found.
• Section 6.1.11 (2) When an error occurs in job execution
• Section 7.15 (5) Type mismatch
(1) Notify errors (job cancellation) that occur during job execution
(a) Set whether to enable or disable notification of errors (job cancellation) that occur
during job execution.
When [Notify errors (job cancellation) that occur during job execution] box is
checked, if job execution is canceled, a value is assigned to the specified tag
component.
(b) Set a tag component to which the value is assigned when this is selected.
1) Tag, Component
Select a tag component to which a value is assigned.
Note that the following tags are not selectable.
Tags for which [Prohibit data writing] is enabled
Tags for which [Array setting] is set
2) Substitute value
Directly enter a substitute value.
The following lists values that can be entered as a substitute value.
Figure 7.64 Setting example of [Notify errors (job cancellation) that occur during job execution]
Table 7.59 Values that can be entered as a substitute value
Data type of tag
component
Values that can be entered as a substitute value
Bit type ON/OFF is selectable.
Single-precision type
Double-precision type
Floating-point type
Up to 16 characters
• Signed decimal notation (Example: -521.98)
• Signed exponential notation (Example: -5.2198E03)
16-bit BCD type Unsigned 16-bit BCD notation 0 to 9999 (Example: 1234)
32-bit BCD type Unsigned 32-bit BCD notation 0 to 99999999 (Example: 12345678)
Character string
Up to 32 characters
For characters that can be used for character strings, refer to the
following:
Appendix 2.3 Characters available for character string constants,
etc.