Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
- 14
10.2 Error Code List
10.2.1 Error codes for the MES interface module
10
TROUBLESHOOTING
(From the previous page)
(To the next page)
Table 10.3 Error codes for the MES interface module
Error code Error name Description Action
0B2Ah
to
0B2Dh
System error
• Please consult your local Mitsubishi
representative.
0B2Eh
DB buffer content error
Data stored in the DB buffer are
invalid. (The CompactFlash card may
be corrupted.)
• Replace the CompactFlash card.
0B2Fh
0B30h
Partial correction of DB
buffer content
A part of invalid data in the DB buffer
has been corrected.
(A part of the DB buffered data in the
CompactFlash card may have been
corrupted.)
0B31h System error
• Please consult your local Mitsubishi
representative.
0B32h DB buffer clear error
Failed to clear the DB buffer. (The
CompactFlash card may be
corrupted.)
• Replace the CompactFlash card.
0B33h DB buffer file error
The DB buffer file is invalid. (The
CompactFlash card may be
corrupted.)
0B34h DB buffer content error
Data stored in the DB buffer are
invalid. (The CompactFlash card may
be corrupted.)
0B35h
to
0B3Ah
System error
• Please consult your local Mitsubishi
representative.
0B3Bh DB buffer full error
Because the DB buffer became full,
the data could not be stored in the DB
buffer.
• Check the network status.
• Ensure a DB buffering capacity.
0B3Ch
System error
• Please consult your local Mitsubishi
representative.
0B3Dh
0B3Eh DB buffering error
Failed in file operation during DB
buffering operation.
• Check the CompactFlash card.
• If the CompactFlash card is
damaged, replace it.
0B3Fh
System error
• Please consult your local Mitsubishi
representative.
0B40h
0B41h DB buffer read error
Data in the DB buffer could not be
read normally.
• Check the CompactFlash card.
• If the CompactFlash card is
damaged, replace it.
0B42h DB buffer clear error Failed to clear the DB buffer.
0B43h DB buffer read error
Data in the DB buffer could not be
read normally.
0B44h DB buffer empty error The DB buffer is empty.
• Do not clear the DB buffer during
resending of DB-buffered data.
• Check the CompactFlash card.
• If the CompactFlash card is
damaged, replace it.