Appendix 3 Setting Information File Format (CSV File Format)
Appendix 3.9 COMPONENT.CSV
APPENDICES
Appendix 3.9 COMPONENT.CSV
(1) File format
(2) Label
Table App.26 File format
Item Description
File name COMPONENT.CSV
File contents
[Device tag settings] - [Component setting] Section 7.8.3 Setting items in Component setting
File format
Table App.27 Label
Label Description
COMPONENT1-1 to
COMPONENT64-256
• Set [Device tag settings] items No. 1 to 64 - [Component setting] items No. 1 to 256.
• Necessary to set the number of labels set with TAG.CSV [COMPNUM]
The label setting following it are ignored.
(Example) When TAG.CSV label [TAG5] has [COMPNUM] of 10
COMPONENT.CSV must set labels COMPONENT5-1 to COMPONENT5-10.
ITEM COMPNAME CPUNO
1
DATATYPE
1
2 3 4
COMPONENT1-1
SINGLE
BIT
DEVICE
5
M12
1)
DECIMAL PLACES
7
0
0
1)
OPERATOR
NONE
8
Flow
Pressure
Opening degree (%)
OPERAND
Item row : Change disabled.
Label column, setting area : Can be changed by the user.
COMPONENT1-2
COMPONENT64-1
COMPONENT64-2
Valve
1
1
2
DOUBLE
REAL
D1003
D5000
W100
FORMAT
6
DEC
DEC
DEC
0
NONE
NONE
DEC
0NONE
STATISTICS
DISABLE
ENABLE AVERAGE
STATTYPE STATSIZE
ENABLE MAXIMUM
DISABLE
1
2
3
4
5
6
7
8
[Device tag settings]
1
COMPONENT64-256
Indicates [Device tag settings] No.1 to 64.
Indicates [Component setting] No.1 to 256.