Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
TROUBLESHOOTING
10.2 Error Code List
10.2.1 Error codes for the MES interface module
10
- 15
9
XML MESSAGE
FORMAT
10
TROUBLESHOOTINGAPPENDICESINDEX
(From the previous page)
(To the next page)
Table 10.3 Error codes for the MES interface module
Error code Error name Description Action
0B45h DB buffer content error
Data stored in the DB buffer are
invalid.
• Check the CompactFlash card.
• If the CompactFlash card is
damaged, replace it.
0B46h
System error
• Please consult your local Mitsubishi
representative.
0B47h
0B48h
Error in conversion from
character string to number
Character strings could not be
converted to numerical values.
• Change the setting so that type
conversion will be available in any
case.
0B49h System error
• Please consult your local Mitsubishi
representative.
0B4Ah
Error in conversion from
character string to number
Character strings could not be
converted to numerical values.
• Change the setting so that type
conversion will be available in any
case.
0B4Bh System error
• Please consult your local Mitsubishi
representative.
0B4Ch
Error in conversion from
character string to number
Character strings could not be
converted to numerical values.
• Change the setting so that type
conversion will be available in any
case.
0B4Dh System error
• Please consult your local Mitsubishi
representative.
0B4Eh
Error in conversion from
character string to number
Character strings could not be
converted to numerical values.
• Change the setting so that type
conversion will be available in any
case.
0B4Fh
to
0B52h
System error
• Please consult your local Mitsubishi
representative.
0B53h
Overflow or zero divide
error
Assignment to the tag component or
input argument and input/output
argument of stored procedure was not
possible. (Overflow)
Division by zero was attempted.
• Check the data type or the
substitute value of the tag
component or input argument and
input/output argument of stored
procedure.
• Change the setting to avoid division
by zero.
0B54h Operation error Invalid operation was performed.
• Change the setting so that any
invalid operation will not performed.
0B55h System error
• Please consult your local Mitsubishi
representative.
0B56h Trigger buffer full error The trigger buffer became full.
• Reduce the frequency of job
startups and their processing loads.
0B57h
to
0B63h
System error
• Please consult your local Mitsubishi
representative.
0B64h DB buffering write error Failed to write data to the DB buffer.
• Change the setting of the DB
buffering capacity to ensure a
sufficient free space on the
CompactFlash card.
• Check if the CompactFlash card is
damaged or not.