Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
8
DB CONNECTION SERVICE AND SETTING TOOL
8.8 Output Log Specifications
8
- 24
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
SETTINGS AND
PROCEDURE TO
OPERATION
5
INSTALLATION AND
UNINSTALLATION
6
FUNCTIONS
7
MES INTERFACE
FUNCTION
CONFIGURATION TOOL
8
DB CONNECTION
SERVICE AND
SETTING TOOL
8.8 Output Log Specifications
This section explains the output log format for the SQL failure log and access log shown
Section 8.8.1 or later.
[Date] [Error code] Message Line feed
*1 For error codes, refer to the following:
Section 10.2 Error Code List
Table 8.10 Output log format for the SQL failure log and access log
Item Description
Output
character
[Date]
Year
1st to 4th bytes at the head
of the line
Four-digit integer for year (Numbers)
Year - Month delimiter
5th byte at the head of the
line
"/" (Slash: 2Fh)
Month
6th and 7th bytes at the
head of the line
2-digit integer (01 to 12) (Numbers)
Month - Day delimiter
8th byte at the head of the
line
"/" (Slash: 2Fh)
Day
9th and 10th bytes at the
head of the line
2-digit integer (01 to 31) (Numbers)
Day - Hour delimiter
11th byte at the head of the
line
" " (Space: 20h)
Hour
12th and 13th bytes at the
head of the line
2-digit integer (00 to 23) (Numbers)
Hour - Minute delimiter
14th byte at the head of the
line
":" (Colon: 3Ah)
Minute
15th and 16th bytes at the
head of the line
2-digit integer (00 to 59) (Numbers)
Minute - Second delimiter
17th byte at the head of the
line
":" (Colon: 3Ah)
Second
18th and 19th bytes at the
head of the line
2-digit integer (00 to 59) (Numbers)
Second - Millisecond delimiter
20th byte at the head of the
line
"." (Period: 2Eh)
Millisecond
21th and 23th bytes at the
head of the line
3-digit integer (000 to 999) (Numbers)
Millisecond - Error code delimiter
24th byte at the head of the
line
" " (Space: 20h)
[Error code]
*1
25th and 34th bytes at the
head of the line
Alphanumeric character of "0x" + 8-digit
hexadecimal
Error code - Message delimiter
35th byte at the head of the
line
" " (Space: 20h)
Message
36th byte at the head of the
line or later
According to the specifications of each log
Line feed End of line CR + LF (0Dh, 0Ah)