Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
- 18
10.2 Error Code List
10.2.1 Error codes for the MES interface module
10
TROUBLESHOOTING
(From the previous page)
(To the next page)
Table 10.3 Error codes for the MES interface module
Error code Error name Description Action
0BA6h
Wait for DB access
(program execution)
completion timed out
No response has returned, from DB
when accessed the database or from
the program being executed. (An
Ethernet communication error has
occurred.)
• Check the Ethernet connection.
• Check if [Server service settings] is
correct.
• Check if the ODBC setting is
correct.
• Check if the database is operating
normally.
• Check if the program specified for
program execution has been
completed.
• In [DB Connection Service Setting
Tool], increase the DB access
timeout value.
• Check if the processing load of the
server computer is excessively
high.
• Check if data volume in the data
base is exceeding the specified
capacity of the personal computer.
• Check if the number of selected/
updated records are extreme when
selecting or updating.
0BA7h System error
• Please consult your local Mitsubishi
representative.
0BA8h SELECT execution error Failed to execute SELECT. • Check the sent SQL text and
database contents.
• Check if the table and field settings
are correct.
• Check that reserved terms of the
database are not set for table
names and field names.
0BA9h COMMIT execution error Failed to execute COMMIT.
0BAAh
ROLLBACK execution
error
Failed to execute ROLLBACK.
0BABh DB update error Failed to update the DB.
• Check the sent SQL text and
database contents.
• Check if the table and field settings
are correct.
• Check that reserved terms of the
database are not set for table
names and field names.
<When the database is Microsoft
®
Access
®
>
• Check if 128 or more fields are set
for update actions.
• Check if multiple accesses have
been made to one file at the same
time (accesses from multiple MES
interface modules).