Mitsubishi Electronics QJ7MES96 Thermostat User Manual


 
10
- 20
10.2 Error Code List
10.2.1 Error codes for the MES interface module
10
TROUBLESHOOTING
(From the previous page)
(To the next page)
Table 10.3 Error codes for the MES interface module
Error code Error name Description Action
0BBDh
Execution error (Program
execution function)
Failed to log on to the application
server.
• Check if the program specified with
the program execution function is
executable with the specified
account.
• After creating an account used for
the program execution function, be
sure to log in once at least.
• A user with an empty password
cannot be specified.
Set a password for the specified
user.
0BBEh
Execution error (Program
execution function)
The application server has failed to
acquire user-identifying information.
• Check if the program specified with
the program execution function is
executable with the specified
account.
0BBFh
The profile of the specified user was
not found in the application server.
0BC0h
The application server has failed to
add a privilege for program execution.
0BC1h
The application server has failed to
load the user profile.
• Check if the program specified with
the program execution function is
executable with the specified
account.
0BC2h
The application server has failed to
add an access right for screen display.
0BC3h
The application server has failed to
start a program.
0BC4h Failed to retrieve a loaded user file.
0BC5h
The application server has failed to
terminate exclusion control.
0BC6h
DB connection service
version error
Function incompatible with DB
Connection Service version of
connection target is used.
• Install the latest version of DB
Connection Service to a server
computer of the connection target.
0BC7h
0BC8h
Stored procedure
execution error
The stored procedure execution has
been failed.
• Check if the settings of the stored
procedures, return values, and
arguments are correct.
• Check if the data type between the
argument and the input argument
and input/output argument of the
stored procedure to be passed are
the same.
• Check that reserved terms of the
database are not set for the stored
procedure names.
0C00h
to
0C56h
System error
• Please consult your local Mitsubishi
representative.
0C80h
CF card check error
(event log writing)
Failed to access the CompactFlash
card during event log output.
• Check if the CompactFlash card is
damaged.
• Turn the power OFF and ON, or
reset the programmable controller
CPU.
0C81h
CF card full error (event
log writing)
Remaining capacity of the
CompactFlash card is not sufficient for
writing the event log.
• Check the capacity of the
CompactFlash card.