ReadiVoice Administration & Maintenance Guide
150 Proprietary & Confidential
When you run the
diagnose
utility:
1 The bridge you’re testing calls you at the number you specified, using the
first bridge resource to be tested.
2 When you answer the call, the bridge plays three numbers that identify
the card, span, and channel on which the call is being made.
In an IP system, the bridge plays a single number indicating the card on
which the call is being made.
3 When you hang up, the bridge calls you on the next resource to be tested
and repeats the process until it completes the test.
4 For each test call completed, the utility writes a line to a log file.
The log file is specified in the
diagnosticlogfile
parameter of the
.odprocrc
file. The default setting is:
diagnosticlogfile = /rahome/bin/TTU.log
If this file exists, the utility appends the new test call records to it.
Otherwise, it creates the file, adds a heading, and writes the records.
To start dial-out testing:
1 Open a Telnet session to the CACS as user cnow, and switch user to root.
2 Change to the
/rahome/utils
directory.
3 Type
./diagnose
and press ENTER.
You see:
4 Type the ID of the bridge and press
ENTER. To find bridge IDs, go to the
Bridges page in System Administration (see page 18).
You see:
5 Enter the telephone number at which you want the bridge to call you
exactly as it should be dialed. Type only the digits, with no parentheses
or dashes, and then press
ENTER.
You see:
To quit, press ’q’:
To Go To Previous Step, Press ’p’:
Enter the ID of the Bridge to Test:
Enter the Phone Number to Dial Out To:
Enter Range of Cards:
From: