Configuring the ReadiVoice System
Proprietary & Confidential 123
Changing the Talker Update Frequency
Through the Operator and Moderator interfaces (and the APIs), the
ReadiVoice system can report which two channels in a conference have talk
slots. By default, talker information is updated every two seconds, but this
interval can be lengthened to reduce the load on the system.
To change the talk slot update interval for the system:
1 Open a Telnet session to the CACS and log in as cnow (or log directly into
the CACS as root and switch user to cnow).
2 Open the
.odprocrc
file for editing, and find the
[bridgeInt]
section.
The
updateIntervalFrequency
keyword sets the talker update
frequency. By default, it’s set as follows:
3 To reduce the update frequency (lengthen the interval), change the value
to an integer greater than 2. Then, save the
.odprocrc
file.
4 As root, stop and restart the ReadiVoice system as described in “Stopping
and Restarting ReadiVoice Processes” on page 111.
Caution!
Perform the following procedure after operational hours. Don’t reduce the interval to
less than two seconds.
[bridgeInt]
...
updateIntervalFrequency = 2