Mitsubishi Electronics Q173CPU(N) Home Security System User Manual


 
14 - 6
14 ROM OPERATION FUNCTION
POINT
Even if a DIP switch setting is changed on the way after the power supply on,
"Operation mode" is not changed. Be sure to turn on or reset the power supply of
Multiple CPU system to change a DIP switch setting.
(2) Applicable data into ROM
The data contents batch written to the internal FLASH ROM by ROM writing are
shown below. Backup data except the followings (current position of servomotor in
absolute position system, home position and latch device, etc.) cannot be written
to the internal FLASH ROM.
(a) Content of applicable data into ROM
SV13 SV22
System setting data System setting data
Each parameter for servo control Each parameter for servo control
Servo program Servo program
Motion SFC parameter Motion SFC parameter
Motion SFC program Motion SFC program
— Mechanical system program
(Note-1)
— Cam data
(Note-1)
(Note-1) : Mechanical system program and cam data are "applicable data into ROM",
when using the SV22.