7 OPERATION CONTROL PROGRAMS
F/FS G
7.10.3 Logical AND :
Format (S1) (S2) Number of basic steps 4
[Usable data]
Usable Data
Word device Constant
Setting
data
Bit device
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
(S1)
— — — — — — — —
(S2)
— — — — — — — —
: Usable
[Setting data]
Setting data Description Data type of result
(S1)
(S2)
Data which will be ANDed Logical type (true/false)
[Functions]
(1) The data specified with (S1) and the data specified with (S2) are ANDed.
[Errors]
(1) An operation error will occur if:
• (S) is an indirectly specified device and its device No. is outside the range.
[Program examples]
(1) Program which sets M100 when M0 and X0 are both 1
SET M100 = M0 X0
M100
1
M0
1
1
(True)
X0