1 - 90
1 OVERVIEW
Setting items for each module (Continued)
Number of usable modules
Module name Item Setting range Initial value
Q173CPU(N) Q172CPU(N)
First I/O No. 00 to FF0 (in units of 16 points) 0
Number of I/O points 0/16/32/64/128/256 16
High-speed read setting Used/Unused Unused
QX /
QX
-S1
Input module
Input response time setting
(setting for high-speed
input module in
parentheses)
1/5/10/20/70 ms
(0.1/0.2/0.4/0.6/1 ms)
10 ms
(0.2 ms)
First I/O No. 00 to FF0 (in units of 16 points) 0
QY Output module
Number of I/O points 0/16/32/64/128/256 16
First I/O No. 00 to FF0 (in units of 16 points) 0
Number of I/O points 0/16/32/64/128/256 16
Input response time setting 1/5/10/20/70 ms 10 ms
QH /QX Y
Input/Output
composite
module
High-speed read setting Used/Unused Unused
First I/O No. 00 to FF0 (in units of 16 points) 0
Input range setting
4 to 20mA/0 to 20mA/1 to 5V/0
to 5V/-10 to 10V/0 to 10V/User
range
4 to 20mA
Temperature drift
compensation
Used/None Used
Resolution mode Normal/High Normal
Q6 AD /
Q6
AD-
Analogue input
module
(Note-1)
Operation mode
Normal (A/D
conversion)/Offset gain setting
Normal
(A/D
conversion)
First I/O No. 00 to FF0 (in units of 16 points) 0
Output range setting
4 to 20mA/0 to 20mA/1 to 5V/0
to 5V/-10 to 10V/User range
4 to 20mA
HOLD/CLEAR function
setting
CLEAR only CLEAR
Output mode
Normal (Asynchronous)/
Synchronous output
Normal
(Asynchro-
nous)
Resolution mode Normal/High Normal
Q6 DA /
Q6
DA-
Analogue
output module
(Note-1)
Operation mode
Normal (D/A conversion)/
Offset gain setting
Normal
(D/A
conversion)
Total 256
points or less
Total 256
points or less
(Note-1) : A maximum of 4 modules, analogue input modules and analogue output modules, can be used.