7 - 53
7 OPERATION CONTROL PROGRAMS
F/FS G
7.9.4 Device input : DIN
Format DIN(D), (S) Number of basic steps 4
[Usable data]
Usable Data
Word device Constant
Setting
data
Bit device
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
(D) —
— — — — — — — —
(S)
— — — — — — — — — —
: Usable
[Setting data]
Setting data Description Data type of result
(D) Input destination data
(S) Input source bit data
Data type of (D)
(Integer type)
[Functions]
(1) The bit data specified with (S) is input to the data specified with (D).
(2) Specify a multiple of 16 as the device No. of the bit data specified with (S).
(3) If the type of (D) is a 16-bit integer type, 16 points of the (D) data, starting at the
least significant bit, are input in order to the bit devices headed by the one
specified with (S).
(4) If the type of (D) is a 32-bit integer type, 32 points of the (D) data, starting at the
least significant bit, are input in order to the bit devices headed by the one
specified with (S).
[Errors]
(1) An operation error will occur if:
• (D) or (S) is an indirectly specified device and its device No. is outside the
range.
• (S) is an indirectly specified device and its device No. is not a multiple of 16.
[Program examples]
(1) Program which inputs the data of X0-XF to D0
DIN D0, X0
D0
0 0 1 0 0 1 1 1 0 0 0 0 1 1 1 1
b0b15
0 0 1 0 0 1 1 1 0 0 0 0 1 1 1 1
X0 XF